Non-flow-pattern dependent method study for velocity profile estimation using a electrical capacitance tomography

dc.contributor.authorSankowski, Dominik
dc.contributor.authorMosorov, Volodymyr
dc.date.accessioned2015-06-03T11:14:44Z
dc.date.available2015-06-03T11:14:44Z
dc.date.issued2009
dc.description.abstractThis paper presents an study of the non-flow-pattern dependent method permitting a solid velocity field to be unambiguously calculated with higher robust using a twin-plane electrical capacitance system. It is based on a spectrum analysis of the pixel values of both cross-sections of the tomographic system. The numerical results of flow velocity measurement using the proposed method against the correlation method are presented.en_EN
dc.formatapplication/pdf
dc.identifier.citationZeszyty Naukowe Politechniki Łódzkiej. Elektryka., 2009 z.114 Spec. s.57-61
dc.identifier.issn0374-4817
dc.identifier.otherP-2090
dc.identifier.other0000022552
dc.identifier.otherW serii gł. nr 1023.
dc.identifier.urihttp://hdl.handle.net/11652/358
dc.language.isoen
dc.publisherWydawnictwo Politechniki Łódzkiejpl_PL
dc.publisherLodz University of Technology. Pressen_EN
dc.relation.ispartofseriesZeszyty Naukowe Politechniki Łódzkiejpl_PL
dc.titleNon-flow-pattern dependent method study for velocity profile estimation using a electrical capacitance tomography
dc.typeArtykuł
dc.typeArticleen_EN

Pliki

Oryginalne pliki

Teraz wyświetlane 1 - 1 z 1
Brak miniatury
Nazwa:
Non-flow-pattern_dependent_method_Sankowski_2009.pdf
Rozmiar:
395.21 KB
Format:
Adobe Portable Document Format