Innovative single and bifurcated coronary stents: from braiding to flexibility

dc.contributor.authorKocaman, Recep Türkay
dc.contributor.authorMiksch, Roxana
dc.contributor.authorAnzer, Corinna
dc.contributor.authorGroßer, Karline
dc.contributor.authorFicker, Frank
dc.date.accessioned2022-11-22T12:24:39Z
dc.date.available2022-11-22T12:24:39Z
dc.date.issued2022
dc.description.abstractIn this study, single and bifurcated coronary stent samples were fabricated nearly in real use sizes using variation braiding technology. Fabrication methods of single and bifurcated coronary stents were introduced and stent diameters, braiding angles, cover factors and flexibility properties of single stents were evaluated according to their process parameters.en_EN
dc.identifier.citationKocaman R. T., Miksch R., Anzer C., Großer K., Ficker F., Innovative single and bifurcated coronary stents: from braiding to flexibility. W: AUTEX 2022 : 21st World Textile Conference AUTEX 2022 - AUTEX Conference Proceedings, Lodz University of Technology Press, Lodz 2022, s. 163-167, ISBN 978-83-66741-75-1, doi: 10.34658/9788366741751.34.
dc.identifier.doi10.34658/9788366741751.34
dc.identifier.isbn978-83-66741-75-1
dc.identifier.urihttp://hdl.handle.net/11652/4466
dc.identifier.urihttps://doi.org/10.34658/9788366741751.34
dc.language.isoenen_EN
dc.page.numbers. 163-167
dc.publisherWydawnictwo Politechniki Łódzkiejpl_PL
dc.publisherLodz University of Technology Pressen_EN
dc.relation.ispartofAUTEX 2022 : 21st World Textile Conference AUTEX 2022 - AUTEX Conference Proceedings, Lodz University of Technology Press, Lodz 2022, ISBN 978-83-66741-75-1, doi: 10.34658/9788366741751
dc.rightsDla wszystkich w zakresie dozwolonego użytkupl_PL
dc.rightsFair use conditionen_EN
dc.rights.licenseLicencja PŁpl_PL
dc.rights.licenseLUT Licenseen_EN
dc.subjectbraidingen_EN
dc.subjectbifurcateden_EN
dc.subjectcoronary stenten_EN
dc.subjectflexibilityen_EN
dc.subjectnitinolen_EN
dc.subjectplecionypl_PL
dc.subjectrozwidlonypl_PL
dc.subjectstent wieńcowypl_PL
dc.subjectelastycznośćpl_PL
dc.subjectnitinolpl_PL
dc.titleInnovative single and bifurcated coronary stents: from braiding to flexibilityen_EN
dc.typeartykuł - konferencjapl_PL
dc.typearticle - conferenceen_EN

Pliki

Oryginalne pliki

Teraz wyświetlane 1 - 1 z 1
Brak miniatury
Nazwa:
34_Innov_single_Kocaman_Autex_2022.pdf
Rozmiar:
970.77 KB
Format:
Adobe Portable Document Format
Opis:

Licencja

Teraz wyświetlane 1 - 1 z 1
Brak miniatury
Nazwa:
license.txt
Rozmiar:
1.71 KB
Format:
Item-specific license agreed upon to submission
Opis:

Kolekcje