Frequency dependence of the Kerr constant in nynas nytro 3000 oil determined by the polarimetric method
Date
2018Author
Poborska, Julita
Dąbrówka, Dominika
Chwirot, Maksymilian
Ledzion, Rafał
Izdebski, Marek
Kucharczyk, Włodzimierz
Metadata
Show full item recordAbstract
Frequency dependence of the Kerr constant in nynas nytro 3000 oil determined by the polarimetric method
A frequency dependence of the Kerr constant K in transformer oil
Nynas Nytro 3000 within a frequency range 117-5017 Hz is determined.
An averaged value (2.30 ± 0.03)·10ˉ¹⁵ m/V² for K is obtained. The
constant is found to be weakly frequency dependent and approaches its
maximum 2.37·10ˉ¹⁵ m/V² at about 3000 Hz. The Kerr constant is of
comparable value to that observed in other mineral oils employed
previously in measurements of the quadratic electro-optic effect and
the electrostriction in crystals. Częstotliwościowa zależność stałej Kerra w oleju nynas nytro 3000 określona metodą polarymetryczną
W zakresie częstotliwości 117 Hz – 5017 Hz przeprowadzono pomiary stałej Kerra K oleju transformatorowego Nynas Nytro 3000. Otrzymana średnia wartość stałej wynosi (2.30 ± 0.03)·10ˉ¹⁵ m/V² w okolicach 3000 Hz osiąga ona maksymalną wartość 2.37·10ˉ¹⁵ m/V² Wyniki pokazują, że wielkość stałej Kerra
w badanym oleju jest zbliżona do wartości obserwowanych w poprzednio badanych olejach więc może on być wykorzystany jako ciecz immersyjna w pomiarach
współczynników kwadratowego efektu elektrooptycznego oraz elektrostrykcji w kryształach.