Grudzień, KrzysztofChaniecki, ZbigniewNiedostatkiewicz, MaciejRomanowski, AndrzejSankowski, Dominik2015-06-032015-06-032009Zeszyty Naukowe Politechniki Łódzkiej. Elektryka., 2009 z.114 Spec. s.35-400374-4817P-20900000022550W serii gł. nr 1023.http://hdl.handle.net/11652/357Paper will focus on the results of tests with the slender cylindrical silo emptied both gravitationally and in controlled manner. The influence of the initial density, wall roughness, height and velocity on the emptying process will be presented. During tests values of the vertical and horizontal accelerations on the silo wall were measured, the effect of the outlet velocity and level of the dynamic effects were compared. Results will be presented in the form of continuous graphs, which allow to analyse the entire process in simpler way comparing to tomographic images form. It is a better form of presentation in order to work out settings for process control, as well.application/pdfenMeasurement of dynamic pulsations in bulk solid during silo discharging using ECT methodArtykuł