Monitoring of solids behaviour during gravitional flow in rectangular silo
(Wydawnictwo Politechniki ŁódzkiejLodz University of Technology. Press, 2009)
This paper is focused on the application of Electrical Capacitance Tomography (ECT) to gravitational flow of bulk solid in rectangular silo investigation. In order to measure the materials distribution inside a vessel, a ...
Design of a new sensor to improve accuracy of ECT images
(Wydawnictwo Politechniki ŁódzkiejLodz University of Technology. Press, 2009)
Electrical capacitance tomography (ECT) has been successfully applied in many industrial fields. However, the resolution of ECT still needs to be improved so that it can be used in a wider scope. As a first attempt to ...